TYPE
(AWS) |
Air
Conditioned Storage Before Opening
RH= Relative Humidity |
Dry
Rod Oven Holding Temperature. after opening |
After
exposure to moisture a sufficient amount of time to affect weld quality |
| Recondition
Step #1 |
Rebake Step #2 |
Cellulose
EXX10
EXX11
EXX20 |
70-110ºF
(21-43ºC)
50% max. RH |
100-120ºF
(38-49ºC) |
Not Recommended |
Titania
EXX12
EXX13
EXX14 |
70-110ºF
(21-43ºC)
50% max. RH |
100-120ºF
(38-49ºC) |
180-230ºF
(82-110ºC)
1/2 hour |
250-300ºF
(121-149ºC)
1 hour |
Iron Powder M.S.
EXX24
EXX27 |
70-110ºF
(21-43ºC)
50% max. RH |
100-120ºF
(38-49ºC) |
180-230ºF
(82-110ºC)
1/2 hour |
400-500ºF
(204-260ºC)
1/2 hour |
Iron Powder Low Hydrogen
EXX18
EXX28Low Hydrogen
EXX15
EXX16
Low Hydrogen High Tensile
EXXX15
EXXX16
EXXX18 |
70-110ºF
(21-43ºC)
50% max. RH |
250-300ºF
(121-149ºC) |
180-220ºF
(82-104ºC)
1- 1/2 hours |
650-750ºF
(343-399ºC)
1 hour |
Stainless
EXXX-15
EXXX-16 |
40-120ºF
(4.5-49ºC)
60% (+/- 10%) RH |
250-300ºF
(121-149ºC) |
180-220ºF
(82-104ºC)
1- 1/2 hours |
500-600ºF
(260-316ºC)
1 hour |
Inconel
Monel
Nickel
Hard Surfacing |
40-120ºF
(4.5-49ºC)
60% (+/- 10%) RH |
150-200ºF
(66-93ºC) |
180-230ºF
(82-110ºC)
1/2 hour |
Not Recommended |
Brasses
Bronzes |
40-120ºF
(4.5-49ºC)
60% (+/- 10%) RH |
150-200ºF
(66-93ºC) |
Not Recommended |
| Granulated or Agglomerated Flux |
40-120ºF
(4.5-49ºC)
60% (+/- 10%) RH |
100-200ºF
(38-93ºC) |
Contact Manufacturer
for Specific Temperatures |
Flux Cored Wire
EXXT-1
EXXT-2
EXXT-5
EXXT-G |
40-120ºF
(4.5-49ºC)
60% (+/- 10%) RH |
200-300ºF
(93-149ºC) |
Contact Manufacturer
for Specific Temperatures |